Reconnected down looking camera firewire cable at the Video Rack.
0700 - cycled VCSEL power
0826 - BDIFR reported nan. Seemed to be an event between 0820 - 0824 that lead to this drop out which effected the QC values as well.
0956 - Short drop in 2D-C data ~ 90 seconds, followed by several other, smaller drops throughout the rest of the flight.
1013 - BDIFR values returned, but data does not appear within tolerance.
SATCOM worked on the ground and for a few minutes after takeoff, then dropped out for the remainder of the flight.
UFT: 35 - 66 deg F
Post Flight Maintenance
Cleaned glass on IRT, VIST, RSTT
Cleaned glass on IRB, VISB, RSTB, RSTB1
Cleaned glass on 2D-S, HVPS, CDP x2
Checked butanol level in RAF CN - good
Blew out DPB and DPT
Blew out all radome pressure lines from transducer fittings toward drain ports. Moisture found in T-fittings of QCR, BDIFR (Right), and ADIFR (Bottom). Moisture also found in drain lines.
1 Comment
David Allbee
Tech: D. Allbee
March 11, 2024
Taxi - 0646
Takeoff - 0654
Landed - 1249
Pre Flight
0700 - cycled VCSEL power
0826 - BDIFR reported nan. Seemed to be an event between 0820 - 0824 that lead to this drop out which effected the QC values as well.
0956 - Short drop in 2D-C data ~ 90 seconds, followed by several other, smaller drops throughout the rest of the flight.
1013 - BDIFR values returned, but data does not appear within tolerance.
SATCOM worked on the ground and for a few minutes after takeoff, then dropped out for the remainder of the flight.
UFT: 35 - 66 deg F
Post Flight Maintenance