• No labels

1 Comment

  1. Unknown User (munnerly)

    3Sept2019

    PF10

    Munnerlyn


    Preflight

    dsm305 (nose) red on status page, no data in Aeros, does not respond to ping. Five reboots. Connected Surface Pro to console port in back of ADS. Finally works, no commands given to 305.

    Dave cleaned VCSEL just prior to flight. laser intensity now above 1100.

    A2D cards show no evidence of channel shifting.

    Cory says DIOV01_LWOO, DIOV32_LWOO and DIOV64_LWOO are low, cycled power, now they're good. DIOV01_RWOI, DIOV32_RWOI and DIOV64_RWOI are good

    DPR stuck in rebalance, cycled power, now good and close to DPL.


    12:14Z    Wheels up, dsm305 still working.

    12:21Z    Cameras stopped, cycled stop and start

    12:29Z    dsmLWO stopped, cycled power

    12:31Z    dsmRWO stopped, cycled power

    12:39Z    cloud, histograms on all probes, images present on both 2DCs

    13:24Z    on station

    14:00Z    Aspen installed on Stipo's computer so he can view dropsonde data realtime.

    14:39Z    L6 (dropsonde) headset can talk but not listen. Replaced both headset and extension and checked connections inside jacks, didn't fix. Original parts back, no replacements used. Will need to look inside wall mount box on maint day. He can hear communication on red "pilot" button but nothing else. Changing my mind about opening wall box, refering to mechs via lead tech instead.

    17:30Z    dsm305 still working