Data from the 7m TRH has been intermittent for more than a month.
Here's a typical dropout, where the unit quits reporting, then 15
hours later comes alive, with startup messages:
Code Block |
---|
2010 10 02 14:07:54.4656 0 40 \x00\x00\r Sensor ID16 data rate: 1 (secs)\n 2010 10 03 05:28:49.2103 5.525e+04 29 \rcalibration coefficients:\r\n 2010 10 03 05:28:49.2517 0.04144 21 Ta0 = -4.042937E+1\r\n 2010 10 03 05:28:49.2827 0.03095 21 Ta1 = 1.022852E-2\r\n 2010 10 03 05:28:49.3134 0.0307 21 Ta2 = -2.096747E-8\r\n 2010 10 03 05:28:49.3445 0.0311 21 Ha0 = -1.479133E+0\r\n 2010 10 03 05:28:49.3773 0.03286 21 Ha1 = 3.554063E-2\r\n 2010 10 03 05:28:49.4057 0.02836 21 Ha2 = -1.382833E-6\r\n 2010 10 03 05:28:49.4390 0.03329 21 Ha3 = 3.354407E-2\r\n 2010 10 03 05:28:49.4693 0.03031 21 Ha4 = 3.666422E-5\r\n 2010 10 03 05:28:49.8050 0.3357 29 TRH16 4.91 94.96 4474 3057\r\n |
Email from Ned:
the TRH at 7m now seems to be re-appearing during the night time and then at about 8am it drops out again...
http://www.eol.ucar.edu/isf/projects/BEACHON_SRM/isfs/qcdata/plots/20101001/Tprof_20101001.png
My guess is that it is a power problem, either in the cable, or corrosion in the unit. This unit and
cable was replaced on 7/22. The problem before was different, looking like a RS232 problem, where
I don't think we saw the bootup messages we're seeing now. https://wiki.ucar.edu/x/vBWdAw