- Most sonics are reporting NA, though they did work initially. Assuming this is ice related (try more heating?), but might check with Campbell to see if a configuration change would help. See table below
- Most EC150s also show missing data. However, in at least one case, I've found the EC150 data to be okay – just missing because statsproc processes it in a group with the sonic data that ARE bad. Hopefully, fixing the sonics will bring back the EC150 values.
- A thermocouple appears to have been plugged in at sh on 19 Dec, but seems to have died on 21 Dec – just 2 days later. While it was plugged in, the data look good, though not exactly like tc (maybe a good thing). I do see noise above 3Hz during the day and 8Hz at night.
- Rfan.3m.prs is bad (T/RH ok). Housing should be replaced? DONE, old housing had no fan!
- Rlw.in.2m.prs not reporting (in the CVF4 housing) – another Binder issue? DONE, mote wasn't sampling, then Rlw.in wanted to be opened up all the way and reassembled.
- Tsoil.mw is all -273. Hopefully, just a loose Binder connector
.DONE, was loose Binder. - P.2m.prs was missing horizonal pipe mount. FIXED
- HRXL.cc stopped reporting 24 Dec.
...