Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

43 meters, S/N 1167, port ttyS17.Prior to installing this unit the total power load of the adam was

Data system power

without 43m 7500

13.0 V

...

1.4 A

18.

...

2 Watts

with 43m 7500

12.6 V

...

3.0 A

...

37.8 Watts

settled to

12.8 V

...

2.3 A

...

29.4 Watts

power difference

 

 

11.2 Watts

Measured power draw of the 43 meter 7500 only, with serial/power meter at
the adam:

43 meter 7500

12.4 V

.87 A

10.8 Watts

Tried to prepare units 813 and 1163 for installation at 30 meters,
but could not get them to boot and run. Red LED at circuit board
would stay on, or blink on and off. It is supposed to go off once
the unit is running. Measured 8 V at the end of 30 meter cable
with unit attached. Need to reduce this loss

...