Commands to change the sampling rate:

Code Block

# shut down data system

...

  1. adn powers off port 17, power it back on.
    eio 17 1

...


adn

# adn powers off port 17, power it back on.
eio 17 1

# start minicom and turn on local echo (E), line wrap (W) and send a break(F)

...


# Set bandwidth to 20 and RS232 output frequency to 20:

...



minicom ttyS17

...


ctrl-A e

...


ctrl-A w

...


ctrl-A f

...


(Outputs BW(20) (RS232 (Freq 20.0)))

...


(Outputs ?)

...


ctrl-A q

...



# minicom should now be finished

...


eio 17 0

...



# aup will power it up

...


aup

# wait a bit, then

...


ds

...


ctrl-C

...




# If the 7500 doesn't respond, try power cycling it:

...


eio 17 0

...


eio 17 1