Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Code Block
7: uart:ST16654 port:F1000110 irq:104 tx:1371 rx:1169013368 fe:41917 RTS|DTR

11: uart:ST16654 port:F1000130 irq:104 tx:2133 rx:18900757 fe:21542 RTS|DTR

14: uart:ST16654 port:F1000148 irq:104 tx:1809 rx:590564461 fe:3997 RTS|DTR

17: uart:ST16654 port:F1000160 irq:104 tx:1339 rx:17587617 fe:2321 RTS|DTR

Testing at FLAB

We've attempted to simulate the turbulence tower data acquisition configuration at FLAB, with an adam sampling 5 CSAT3 sonics at 20Hz and 1 Licor 7500 whose transmit and signal ground lines are forked to 5 separate serial ports. There is no GPS, CNR1, barometer or 5 TRHs on the test adam. We see no spurious interrupts, and the data system is keeping up with the 1x5 Licor set to 20Hz, 19200 baud. top shows a consistant system idle value between 97 and 80%.
top on the adam at the turbulence tower shows 65-79 % idle