Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
  • Have done my second restart in 24 hours of pillow #3.  We'll try one more attempt to upgrade its software next visit.
  • EC150s (h2o/co2) all died with low signal levels (presumably due to frost) 2 days ago.  Most came back later in the day.  1m.uw came back last night, 1m.ue still hasn't come back.  I'm hoping that the internal heating setting is enabled on all of these.
  • TRH.12m continues to have a dead fan, that will need to be replaced
  • We have not seen a recurrence of the Apogee issue since the cables were swapped.  Since both the original and replacement cables that Apogee sent were their new style, we suspect that the issue we saw before was our termination of the cable that possibly let water in.  Our termination of the new cables was done better.