Around mid-day Ned and Chris measured the guy tensions and those values have been added to the matrix in the blog entry.
On Feb 4, logged into system from Boulder to verify the serial numbers of the licors:
port | SN | assumed height |
---|---|---|
2 | 1163 | 2m (was at 30m |
7 | 1166 | 7m |
20 (was 17) | 1167 | 16m |
14 | now disconnected |
|
11 | 1164 | 43m |
This agrees with the previous configuration, and the move of the 30m unit (SN1163) to 2m, and the swap of the 16m unit (SN1167) to port 20 on the new data system box.
To check the licor serial numbers do:
No Format |
---|
adn # shut down data process
minicom ttySN
ctrl-A F # sends break
(Outputs (RS232 (EOL "0A0D"))) # enable carriage return in output
(Coef ?) # display serial number
(Outputs (RS232 (EOL "0A"))) # new-line termination, resume output
ctrl-A Q # quit minicom
aup # restart data process
ds
ctrl-C # verify sampling rates
|