Final step is to add the remaining 4 sensors (2xTRH, prop, baro).
-------------------------
Round 3, 9/28:
Added TRH, Baro, Prop, Power mote to tripod set-up. All the same S/N as used at #4, except possibly not mote (or TRH fan)
- Some jumping, but doesn't analyze as clear 2Hz with ambient voltage ~0.38V
- Put bag back on, get 0.00V, no noise evident (spectra show a slight bump at 5Hz -- probably A/D conversion artifact)
- Replaced bag by bit of wire mesh, reduced voltage to 0.18V. Also changed mote power switch, which might have been off.