Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

...

We may want to consider having the dsm's send 'hb' heart-beat commands to the motes and re-enable xbee reset values (which only reset if there is no heart-beat received).

14Oct13, ~1Z GMT

Noticing that Tom reported in the mote status that flr was having additional problems I logged in and rserial'd to the xbee's.

ID1 and 2 were reporting but not 17 as noted.   I tried a 'hb<cr>' command and then a simple <cr> and 17 began reporting.

Further commands issued and normal responses were received.

Changed xbee reset timing: was xr=3600 (1hour), to xr=43200 (12hours).   Maybe they should be turned off, however, what i notice is that things work much better after commands are received from the base radio, so we should consider the cron-'hb' i believe.

14Oct13, ~19Z

flr:  The flr motes had outages last night and at least 2 rebooted.   The setting above hadn't gotten 'eeupdate'd so i reset the xr=43200 and stored the setting.   While interacting with them, id2, which had been 'down', again began sending data.

near:  Daily status reported outage of the spn.   All 3 were reporting when i logged in.  I changed id3 to disable the xbee reset, xr=0, to match the other 2 and not be what appears to be problematic hourly resets.   Gordon's cron 'hb' heartbeat is running so we might try setting xr=12hrs, but not yet.