Capped off a connector at the mote with tape to protect it.

 

Site 8 

Measured azimuth angles for 3m and 10m 3D sonics. They measured 222 degs and 308 deg, respectfully.

 

Site 11

We found the data had kept recording at this site, although it wasn't be seen over the network. The modum was having issuesmodem would not connect, and the net_check.sh script (runs at 40 minutes after the hour) would not bring the connection up. Unplugging and re-plugging in the modem  did the trick

The voltage measured was approx 13 volts

.  The CPU at this site is a viper.

On the status web page for the modem, the signal Signal strength was -102 db (clicking showing between 2 and 3 bars) with SNR of 0 for the small existing 6" antenna. We hard wired another larger antenna on, however there was no connected a larger 12" whip antenna, and held it up by hand.  There was no increase in gain so we left it as is.with the 6" antenna. Perhaps hand holding the antenna was not a good test (a worse ground plane than the installed antenna?).

The system battery voltage measured was approx 13 volts (the power monitor on S11 is out). 

Site 15

Measured azimuth angels for 3m and 10m sonics, they were 225 deg and 309 deg respectfully. 

...