- grass Tsoil – probably replace
- init.6m - probably need to replace, but don't have a spare (still at least 6 back at Campbell being repaired) Confirmed a red sonic LED in EC100, and all aspects of installation look fine.
- TRH.8.5m.rel - unknown issue (climbed and replaced SHT sensor, but turned out to be RS422/232 jumpering. Now fixed.)
- mote.20m.rel not sending data (mote console cable Bulgin to standard serial Bulgin connection at 20m doesn't have a purple ring. Retaped and got mote LEDs alive.)
Electric fence is mostly up (to protect CTEMPS fiber).
Dry run IOP is scheduled for tonight: 2200-0000.
Data flow was horrible this morning – cockpit wouldn't connect to streams/nagios showed critical something on almost all dsms. Did an ansible restart_dsm on everything, which got most going (P4 still won't connect, as usual with morning dew).