Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

...

Summary: Stations 1-4 operational, no ISFS staff on site
         Krypton hygrometer needing at stn 4 needing lens cleaning
         winds backing to SE or ESE during the overnight        
         strong southerly winds, warm and very moist daytime    

...

T.2m: ok, stn 1 and 2 slightly cooler than 3-4 around 6:00-6:30 CDT
          stn 3 and 4 slightly cooler (0.5 C) than 1-2 in daytime 1600 16:00 CDT
          stn 4 cools (t2m < t10m) 1 hr earlier in the evening than at stn 1-3
         
RH.2m: 80-100% at night; stns 1 & 2 few %RH less than stn 3; stn 3 few %RH less than stn 4
       55-65 % during day stns 1-3 lower than stn 4
H2O.2m: day:  stns 1-2 are ~1 g/m^3 less than stn 3, stn 3 ~1 g/^3 less than stn4
        stn 1 within 0.5 g/m^3 at night (of stns 2,3), stn 4 0is 0.5 g/m^3 more than stn 2-3

...

T.10m - T.2m: ok, diurnal cycle as expected, very similar at all sites; slight cooling at stn4 as mentioned above for T.2m
H2O.10m - H2O.2m: stn 1 > 0 last night, stn 4 < 0 ~1 g/m^3

...

vh2ov:  below 100 mV, but h2o up 23 gm/m^3
kh2o: stn 4 appears to need 4 needs the sensor cleaned
h2o(licor): ok
lidiag (licor): ok

...