Adding what I can see from logging directly into dsms (there are some problems I'm still looking into that show more data being missing on qctables...)

  •  t29:  TRH T is low.  RH is fine.  Maybe just needs to have new cal re-uploaded? tt: 7m csat3a/ec150 (ttb port 0) not reporting (wasn't plugged in)
  •  tt: 28m csat3a/ec150 (ttt port 0) all nans for co2/h2o (wasn't plugged in)
  •  t0: 2m TRH (t0b port 4) not reporting (bad port 4, moved to t0t port 7)
  •  t0: 3m TRH (t0t port 1) reports all zeros, far less than once a second
  •  t2: 4m TRH (port 3) not reporting
  •  t2: 4m csat3a/ec150 (port 2) not reporting
  •  t7: 4m csat3 (port 0) not reportingldiag always nonzero
  •  t8: issues with dsm serial card (this may be the reason for all the t7/8/9 sensor problems) (dsm replaced, seems fine)
  •  t8: 4m csat3a/ec150 (port 2) not reporting (bad dsm)
  •  t8: 4m TRH (port 3) not reporting (bad dsm)
  •  t8: 4m nano (port 4) reporting bad data (*0100P4\r\n), far less than once a secondinit string only (bad dsm)
  •  t9: 4m csat3a (port 5) not reporting (not installed?reporting in ascii mode, not being parsed (taken back to site to configure)
  •  t10: 4m csat3 (port 0) not reporting (tried other ports, probably not a port problem)
  •  t15: 4m csat3a (port 5) not reporting (wasn't installed)
  •  t17: 4m TRH (not installed?port 3) not reporting (it was earlier) (restarted dsm)
  •  t17: 4m nano (port 4) not reporting (it was yesterday) (restarted dsm)
  •  t18: 4m csat3b (port 5) not reporting (not installed?(it was yesterday) (restarted dsm)
  •  t19: 4m csat3 (port 0) not reporting (box wasn't installed)
  •  t20: 4m TRH (port 3) bad rfan (replaced housing)
  •  t21: 4m csat3a (port 5) not reporting (not installed?needs data cable)
  •  t22: 4m csat3 (port 0) not reporting (box wasn't installed)
  •  t23: soils not reporting (rescanned mote)
  •  t23: 4m TRH (port 3) not reporting (added fuse to port 3)
  •  t24: 4m csat3b (port 5) not reporting (not wasn't installed?)
  •  t25: 4m csat3 (port 0) not reporting (box wasn't installed)
  •  t26: 4m csat3a/ec150 (port 2) not reporting (plugged in power inside box)
  •  t26: 4m csat3a/ec150 (port 2) set in ascii mode, taking box back to base
  •  t27: 4m csat3a (port 5) not reporting (not installed?added data cable)
  •  t28: 4m csat3 (port 0) not reporting (box wasn't installed)
  •  t29:  TRH T is low.  RH is fine.  Maybe just needs to have new cal re-uploaded?
  •  t30: 4m csat3b (port 5) not reporting (not wasn't installed?)
  •  t31: 4m csat3 (port 0) not reporting (box wasn't installed)
  •  t33: 4m csat3b (port 5) not reporting (not installed?updated sonic type in config)
  •  t34: 4m csat3 (port 0) not reporting (box wasn't installed)
  •  t36: 4m csat3b (port 5) not reporting (not wasn't installed?)
  •  t37: 4m csat3 (port 0) not reporting (box wasn't installed)
  •  t39: 4m csat3 (port 5) not reporting (box wasn't installed)
  •  t40: 4m csat3 (port 0) not reporting (box wasn't installed)
  •  t42: 4m csat3b (port 5) not reporting (not wasn't installed?)
  •  t43: 4m csat3 (port 0) not reporting (box wasn't installed)
  •  t45: 4m csat3 (port 5) not reporting (box wasn't installed)
  •  t46: 4m csat3 (port 0) not reporting (box wasn't installed)
  •  t47: 4m nano (port 5) not reporting, most likely ec100 box wiring issue? taking box back to base
  •  t48: 4m csat3b (port 5) not reporting (not wasn't installed?)
  •  t49: 4m csat3 (port 6) not reporting (box wasn't installed)
  •  t49: tsoil not reporting (rest of mote sensors are fine) (replaced)