Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 5.3

...

No Format
adn                                # shut down data process
minicom ttySN                      # N is port number
ctrl-a f                           # sends break
(Outputs (RS232 (EOL "0A0D")))     # enable carriage return in output
(Coef ?)                           # display serial number
(Outputs (RS232 (EOL "0A")))       # new-line termination, resume output
ctrl-a q                           # quit minicom
aup                                # restart data process
ds                                 # wait 10-15 seconds
ctrl-c                             # verify sampling rates