Flight 1:
-2DS and HVPS lost power after takeoff, likely due to luggage bumping into forward power cables at L-6 rack (where power cables from 2DS and HVPS plates plug into power drop box). 2DS power was flickering while HVPS power remained off. Both probes reconnected without issue after we moved the luggage, wiggled power cables at power drop box connection, and reset power on 2DS and HVPS plates.


Fuel Stop (in Sioux CityFalls, IASD):
-Cameras turned off and ethernet cable unplugged/plugged back in
-APU on, ADS power stayed on
-Wing probes turned off to prevent overheating
-Balanced dewpointers
-SATCOM troubleshooting: switch reset, circuit breakers reset, CISCO router reset
-HOLODEC: camera tip heater lost connection after landing  
-PHIPS re-started, still unable to connect (60Hz and 400Hz AI power remains on during flight)

...