The 2m licor connected to /dev/ttyS2 was removed today, and the licors at 16 and 43 meters were reconnected to ports /dev/ttyS17 and /dev/ttyS11 by a BEACHON help person at the sitehelper.
By checking the serial numbers, with the (Coef ?)
command, and comparing against the earlier LICOR log entry, we could determine remotely what unit is connected to what port. Note that the licors at 16 and 43 meters are switched from the previous configuration.
port | height | SN |
---|---|---|
ttyS2 | removed |
|
ttyS7 | 7m | 1166 |
ttyS11 | 43 meters 43m | 1164 |
ttyS14 | 30m | 1163 |
ttyS17 | 16 meters 16m | 1167 |
The data system from the time the licors on port 11 and 17 were enabled on Dec 2, until the next morning, Dec 3 at 10:26 AM MST was configured in the old way, so the data from the licor on port 17, SN 1167 was given an id of 1,310, and the data from the licor on port 11, SN 1164 was given an id of 1,510. So the licor data at 43 meters and 16 meters is cross-identified during that time period.
...
Code Block |
---|
(Outputs (RS232 (EOL "0A") (Labels FALSE) (DiagRec FALSE) (Ndx FALSE) (Aux FALSE) (Cooler FALSE) (CO2Raw TRUE) (CO2D TRUE) (H2ORaw TRUE) (H2OD TRUE) (Temp TRUE) (Pres TRUE) (DiagVal TRUE))) |
...
Code Block |
---|
7: uart:ST16654 port:F1000110 irq:104 tx:1371 rx:1169013368 fe:41917 RTS|DTR 11: uart:ST16654 port:F1000130 irq:104 tx:2133 rx:18900757 fe:21542 RTS|DTR 14: uart:ST16654 port:F1000148 irq:104 tx:1809 rx:590564461 fe:3997 RTS|DTR 17: uart:ST16654 port:F1000160 irq:104 tx:1339 rx:17587617 fe:2321 RTS|DTR |
Testing at FLAB
We've attempted to simulate the turbulence tower data acquisition configuration at FLAB, with an adam sampling 5 CSAT3 sonics at 20Hz and 1 Licor 7500 whose transmit and signal ground lines are forked to 5 separate serial ports. There is no GPS, CNR1, barometer or 5 TRHs on the test adam. We see no spurious interrupts, and the data system is keeping up with the 1x5 Licor set to 20Hz, 19200 baud. top shows a system idle value between 97 and 80%.
top on the adam at the turbulence tower shows 65-79 % idle. Other than the additional low rate serial sensors there is no difference between the 2 systems. They are both writing the full archive to a usbdisk.