• Pirga not using P_RANGE
  • Vbatt not using VIN_RANGE
  • Tbatt not using T_RANGE
  • need to redefine Ixx_RANGE in mA, not A
  • need different dTsoil/dt range
  • T.8.5m.rel dead
  • relt dead (oops, had done "ddn" when using minicom and hadn't brought back up)
  • need Alt range
  • co2 offscale (why?)
  • lconv - no pmon data (got working, but ansibile didn't update config, and config needed to have a suffix defined to work)
  • csat.6m.init dead
  • gps.uconv2 dead
  • pmon.p3, p4, p5 dead
  • Tsoil.grass not right, but others now okay!
  • No labels

2 Comments

  1. Steve Oncley AUTHOR

    Adding the usb power monitor cable to P4 got it working.  All Px should have this cable now.  Rebooting P3 didn't get its pmon working.

  2. Steve Oncley AUTHOR

    First 3 items now fixed.  Apparently, the "plotrange" keyword is only used within <variable ...>, and is ignored (without an error) when further embedded in <linear ...>.