Nice weather after the cold front/rain yesterday. Semmer has left, Andy to arrive Mon, so no pickup for 2 days. I'm the Boss for another 3 days...
Still 38 instrumented towers.
- rne04 supposedly was retensioned yesterday or Thurs. Will wander up there to check. If good, can add RMY.
- tnw02/04/08 supposedly have concrete in place, ready for towers. Will wander out there too to check today. Checking prepping in ops.
- tse05/14/15 will be worked on next week. Prepping in ops.
Issues
- li7500.v07 wanders off with bad values, but 4-hour crontab restart has been bringing it back
- li7500.v06 is similar, but lidiag is aways set, thus no values are coming through statsproc. Will need some action.
- tp01.tse02/07/12 all not reporting – suspect plugged into wrong mote port (only works on right-most port with the new fuses)
- trh.20m.rsw06 still bad. will need action.
- During prepping, have noticed things missing:
- not enough motes. The remaining 2 will be used for the 2 soil installations
- only one mote console cable! (3 have a broken pin). Will repair with spare connector.
- having to use a not-Ted's ethernet cable, since I gave one to CU (thinking I had extra).
- Ted had given away the ubiquiti for tse15. I'm reprogramming the next-to-last spare.