BEACHON Tower Guy-Wire Tensions (lbs).....THIS SHOULD BE AN ON-GOING LOG

Inner to Outer...

South Guy-Wire:

Guy-Wire

7/7/09 Sharon
(7/8/09 Ned)

7/17/09 Ned

8/28/09 Ned

10/01/09
Chris

02/02/10
Chris/Ned

05/28/10
Kurt/Ned

7/22/10
Kurt & company (re-tensioned all
guy wires)

3/29/11
Kurt/Ned

7/31/11
Chris/Ned

Inner (Close to tower)

500 (425)

425

350

375

350

250

385

380

300

 

550 (510)

460

405

450

415

340

385

375

340

 

500 (420)

380

355

350

350

300

395

365

325

 

500 (500)

460

415

450

430

350

375

390

325

 

500 (400)

370

330

325

320

275

440

400

350

Outer (Farthest)

450 (400)

350

330

350

340

290

390

350

335

Northwest Guy-Wire:

Guy-Wire

7/7/09 Sharon
(7/8/09 Ned)

7/17/09 Ned

8/28/09 Ned

10/01/09
Chris

02/02/10
Chris/Ned

05/28/10
Kurt/Ned

7/22/10
Kurt & company
(re-tensioned all
guy wires)

3/29/11
Kurt/Ned

7/31/2011
Chris/Ned

Inner (Close to tower)

600 (490)

450

375

380

360

300

450

440

350

 

550 (500)

450

405

440

400

325

395

390

325

 

450 (500)

470

445

450

450

390

475

440

425

 

600 (500)

450

400

425

400

340

380

390

325

 

440 (415)

410

355

375

355

300

425

390

350

Outer (Farthest)

430 (400) 

360

345

350

340

300

400

390

350

Northeast Guy-Wire (nearest to the road)

Guy-Wire

7/7/09 Sharon
(7/8/09 Ned)

7/17/09 Ned

8/28/09 Ned

10/01/09
Chris

02/02/10
Chris/Ned

05/28/10
Kurt/Ned

7/22/10
Kurt & company
(re-tensioned all
 guy wires)

3/29/11
Kurt/Ned

7/29/11
Chris/Ned

Inner (Close to tower)

580 (470)

440

360

400

395

300

420

410

340

 

600 (550)

500

425

450

440

350

450

450

370

 

680 (670)

590

575

625

610

525

500

550

500

 

500 (460)

450

375

375

380

300

425

400

340

 

600 (525)

500

425

440

405

325

475

425

400

Outer (Farthest)

480 (405)

410

360

400

370

330

450

400

400

Modifications:

090717, jwm     Added readings by Ned Patton on 7/17/09.  Note roughly 100-lb drop on each, but there was no shift on the anchors/base per-paint applied; ie stretching.

090828, egp Anchors did not exhibit any shifting, added new readings to the tables above.

091001, csg  Anchors looked good.  Tensions were fine.  May need some tensioning on South guy-wires soon.

100528, egp  Anchors looked good, not shifting.  Kurt recommends re-tensioning guy wires complete with transits to re-plumb tower.  July 2010?

7/22/10 re-tensioned all guy wires using transits to plumb tower, also replaced 7m & 15m trh cables as well as 7m trh sensor.