Went in knowing that there were lots of issues, related to the high water from the recent storm.  Out from trailer 1300-1700 with Cristina:

S3: Station dead due to water getting into DSM through duct-taped Gordon hole.  Obvious bits of corrosion on power interface board.  Wiped off water on board and replaced blown main fuse, but new fuse blew within a few seconds (DSM LEDs were briefly all green.)  Removed DSM for debugging/replacement.  Capped cables by putting into an empty water bottle.  Strapped lid down on battery box.

S1: Power monitor board blown due to shorting with obvious corrosion.  Replaced with spare we had brought.  Strapped lid down on battery box.

S11: Power monitor board blown due to shorting with obvious corrosion.  Battery cooler lid was ajar.  Left in place.  Strapped lid down on battery box.

S7: Power monitor board obviously had been wet, but still reporting.  However, gain on Vbatt was 0.  Changed with vbg=10 and now get a voltage (though calibration probably isn't correct).  Strapped lid down on battery box.

S15: Water everywhere, but station was working.  Tried cycling power on both sides of Bluetooth, but could get data to flow.  Rebooting DSM brought back the Bluetooth connection.

 