1214 - Cycled VCSEL. Functioned fine for the remainder of the flight.
1216 - Cycled DPR
DP_DPL displaying on AEROS today but intermittent. Only showing data when CAVP_DPL is not railed... Both are unstable.
1245 - Cycled 10um probe. (41K ft) Did not come back right away. Several minutes later, End diode voltages began to rise much like they have in previous flights.
RWO DSM went out 4 times between 1545 and 1620. No action was taken; the DSM came back on its own each time. Notified Chris. He said there was nothing significant in log files, the DSM just rebooted.
All Nose pressures functioned today with no freezing.
1 Comment
David Allbee
Flight Tech - D. Allbee
30Sep2019
Taxi - 1207
Takeoff - 1210
Landed - 1723
Pre-Flight
CAVP_DPL = -46.9
CAVP_DPR = -32767
LSRINT_VXL = 1280
10um - 1 = 0.42 32 = 0.63 64 = 0.37
25um - 1 = 3.42 32 = 2.53 64 = 3.33
RTH1 = 22.43
RTH2 = 22.22
1214 - Cycled VCSEL. Functioned fine for the remainder of the flight.
1216 - Cycled DPR
DP_DPL displaying on AEROS today but intermittent. Only showing data when CAVP_DPL is not railed... Both are unstable.
1245 - Cycled 10um probe. (41K ft) Did not come back right away. Several minutes later, End diode voltages began to rise much like they have in previous flights.
RWO DSM went out 4 times between 1545 and 1620. No action was taken; the DSM came back on its own each time. Notified Chris. He said there was nothing significant in log files, the DSM just rebooted.
All Nose pressures functioned today with no freezing.