TF01 Notes
Technician: Richard Freeman
Date: 07/23/2019
Preflight CDP issue: no communication from DSM LWO to CDP. Probe has power and appears to be functioning properly.
After takeoff: CDP on LWO has serial communication.
L5 rack forward laptop: screen is dark and difficult to read. Most likely a contrast issue need to adjust.
F2DIO1_LDO, F2DIO32_LDO, F2DIO64_LDO are reading as NAN and occaisionally read as in sub-mv range.
R1: minimac still needs ads password for login
Headset R6 cutting in and out on listening. Looks to be a problem with headset jack.
Lost comms with CDP at 16:23.
Cycled left wing power at 16:57. Still have no comms to CDP
17:14 Left camera refocused.
Had issue with right camera not displaying.
Lost data on main power DSM from 18:05 to 18:15 with intermittent reconnects. connection stabilized on its own. will continue to monitor for dropouts.
18:38 - DSM 304 analog card dropping out in aeros intermittently.
18:44 - LWO stopped. Cycled power to LWO which restored operation.CDP still not active.
18:54 - CDP recorded data for about 15 minutes before dropping out again.,
19:54 - Neglected to turn on water system and drain heater in pre-flight. remedied while landed at casper.
1 Comment
John Cowan
TF01 Notes
Technician: Richard Freeman
Date: 07/23/2019
Preflight CDP issue: no communication from DSM LWO to CDP. Probe has power and appears to be functioning properly.
After takeoff: CDP on LWO has serial communication.
L5 rack forward laptop: screen is dark and difficult to read. Most likely a contrast issue need to adjust.
F2DIO1_LDO, F2DIO32_LDO, F2DIO64_LDO are reading as NAN and occaisionally read as in sub-mv range.
R1: minimac still needs ads password for login
Headset R6 cutting in and out on listening. Looks to be a problem with headset jack.
Lost comms with CDP at 16:23.
Cycled left wing power at 16:57. Still have no comms to CDP
17:14 Left camera refocused.
Had issue with right camera not displaying.
Lost data on main power DSM from 18:05 to 18:15 with intermittent reconnects. connection stabilized on its own. will continue to monitor for dropouts.
18:38 - DSM 304 analog card dropping out in aeros intermittently.
18:44 - LWO stopped. Cycled power to LWO which restored operation.CDP still not active.
18:54 - CDP recorded data for about 15 minutes before dropping out again.,
19:54 - Neglected to turn on water system and drain heater in pre-flight. remedied while landed at casper.