More fixes today:
- reseated Bulgin/Bulgin connection (missing a purple ring) for rad.20m.rel
- changed trh.8.5m.rel to RS232 mode (rather than RS422)
- replaced CSAT3A at 6m.init with CSAT3A from 1.5m.a2.rel
- replaced CSAT3A at 1.5m.a2.rel with a CSAT3, requiring a new cable, new mount to be invented, new serial port in RS232 mode. Note that the new mount puts the path about 5cm higher and 3cm further north.
- installed a new sensor for Tsoil.grass.uconv
I <thought> that fixed all sensor issues, but now see a dead CSAT3A at 1.5m.rel. I can't win and the stupid CSAT3A's keep on dying and Campbell hasn't fixed the batch of 5 or 6 bad ones that I shipped to them a month ago....
I still don't know why pmons at uconv, P3 and P5 aren't working.
gps.uconv2 is a known problem that Gary has worked around.
Dry run IOP just starting now (9pm). The PI team is pretty excited, and so are the mosquitos.