Adjusted Guy Wire tensions
- UE - 2 full turns of the turnbuckle
- Fwd R - 165 –> 200
- Fwd L - 180 –> 260
- Aft - 160 –> 200
- UW - 2 full turns
- Fwd R - 90 –> 200 (6 turns) - We made sure to use 2 levels after all the tensions were verified
- Fwd L - 105 –> 200
- Aft - 100 –> 240
- D - 2 full turns
- Aft L - 190 –> 295
- Aft R - 190 –> 330
- Fwd - 179 –> 300
- C - 2 turns
- Aft outer - 250 –> 340
- Aft inner - 200 –> 320
- Fwd R outer - 250 –> 300
- Fwd R inner - 160 –> 300
- Fwd L outer - 260 –> 340
- Fwd L inner - 205 –> 350
Moved Booms/CSAT/EC150 from 2m to 1m
- upwind west at 11:32
- Upwind east at 11:45
- Downwind at 12:14
Swapped USB sticks
- UE
- Pi-1 at 11:56
- Pi-2 at 11:56
- D
- Pi-5 at 12:48
- Pi-6 at 12:48
Cleaned Radiometers
- UW at 11:46
- D at 11:15
Troubleshot 9m Radiometer
- Replaced mote at 1:07
Cleaned Gas Analyzer lenses on C
- 10m at 2:08
- 15m at 2:12
- 20m at 2:15
- 5m at 2:19
- 3m at 2:22
- 2m at 2:23
- 1m at 2:21